dc.description.abstractOver the years of 2000 trough 2003 I had worked at two Centers of Ophthalmology in USA. During my fellowship at Center for Reaserch on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina and at John A. Moran Eye Center University of Utah, Salt Lake City, Utah, I had worked as a member of Apple Korps team on the analyses of four various hydrofilic acrylic intraocular lenses (Hydroview H60M, SC60B-OUV, Aqua Sense a MemoryLens). These explanted IOLs were sent to our Centers from the Ophthalmology Clinics from all over the world due to their opacification. Since the year 2005, after my return from the USA, as an ophthalmologist of Eye Clinic F.D. Roosevelt Hospital, Postgraduate Medical School in Banska Bystrica, I continued working on the analyses of explanted IOLs in close cooperation with above specified US Centers as well as with at the time freshly established European Center BERI in Berlin. Analyses of 7 opacificated IOLs (3 MemoryLens, 1 Aqua Sense, 1 Sofcryl, 1 Oculentis and 1 Acrysof ) was performed at the Eye Clinic in Banska Bystrica. Using examination methods (such as gross macroscopic and microscopic analyses, histochemical staining using Alizarin red and von Kossa method, Scanning electron microscopy -SEM and Electron...en_US
dc.description.abstractSúhrn V rokoch 2000 až 2003 som pracovala v USA na dvoch pracoviskách. Počas môjho fellovship v Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina a v John A. Moran Eye Center, University of Utah, Salt Lake City, Utah som ako člen Apple Korps tímu pracovala na analýze štyroch typov hydrofilných akrylátových umelých vnútroočných šošoviek (Hydroview H60M, SC60B-OUV, Aqua Sense a MemoryLens), ktoré boli do našich centier zaslané z oftalmologických pracovísk celého sveta po explantácii pre ich opacifikáciu. Po návrate z USA som od roku 2005 ako sekundárny lekár Očnej kliniky Slovenskej zdravotníckej univerzity FNsP F.D. Roosevelta v Banskej Bystrici pokračovala v analýze explantovaných umelých vnútroočných šošoviek v spolupráci s horeuvedenými americkými pracoviskami ako aj s novovzniknutým európskym pracoviskom BERI v Berlíne. V Banskej Bystrici bola vykonaná analýza 7 opacifikovaných umelých vnútroočných šošoviek (3 MemoryLens, 1 Aqua Sense, 1 Sofcryl, 1 Oculentis a 1 Acrysof). Pomocou komplexu vyšetrovacích metód (Gross makroskopická a mikroskopická analýza, histochemické farbenia alizarínovou červeňou a metódou von Kossa, elektrónova rastrovacia mikroskopia - SEM a RTG spektroskopická analýza - EDS) sme dokázali,...cs_CZ
dc.languageSlovenčinacs_CZ
dc.language.isosk_SK
dc.publisherUniverzita Karlova, Lékařská fakulta v Hradci Královécs_CZ
dc.titleBiokompatibilita implantátů používaných při mikrochirurgii okask_SK
dc.typedizertační prácecs_CZ
dcterms.created2014
dcterms.dateAccepted2014-03-26
dc.description.departmentDepartment of Ophthalmologyen_US
dc.description.departmentOční klinikacs_CZ
dc.description.facultyLékařská fakulta v Hradci Královécs_CZ
dc.description.facultyFaculty of Medicine in Hradec Královéen_US
dc.identifier.repId81373
dc.title.translatedBiocompatibility of implants used in mikrosurgery of the eyeen_US
dc.title.translatedBiokompatibilita implantátů používaných při mikrochirurgii okacs_CZ
dc.contributor.refereePašta, Jiří
dc.contributor.refereeTěšínský, Pavel
dc.identifier.aleph001708688
thesis.degree.namePh.D.
thesis.degree.leveldoktorskécs_CZ
thesis.degree.discipline-cs_CZ
thesis.degree.discipline-en_US
thesis.degree.programOční lékařstvícs_CZ
thesis.degree.programOphthalmologyen_US
uk.thesis.typedizertační prácecs_CZ
uk.taxonomy.organization-csLékařská fakulta v Hradci Králové::Oční klinikacs_CZ
uk.taxonomy.organization-enFaculty of Medicine in Hradec Králové::Department of Ophthalmologyen_US
uk.faculty-name.csLékařská fakulta v Hradci Královécs_CZ
uk.faculty-name.enFaculty of Medicine in Hradec Královéen_US
uk.faculty-abbr.csLFHKcs_CZ
uk.degree-discipline.cs-cs_CZ
uk.degree-discipline.en-en_US
uk.degree-program.csOční lékařstvícs_CZ
uk.degree-program.enOphthalmologyen_US
thesis.grade.csProspěl/acs_CZ
thesis.grade.enPassen_US
uk.abstract.csSúhrn V rokoch 2000 až 2003 som pracovala v USA na dvoch pracoviskách. Počas môjho fellovship v Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina a v John A. Moran Eye Center, University of Utah, Salt Lake City, Utah som ako člen Apple Korps tímu pracovala na analýze štyroch typov hydrofilných akrylátových umelých vnútroočných šošoviek (Hydroview H60M, SC60B-OUV, Aqua Sense a MemoryLens), ktoré boli do našich centier zaslané z oftalmologických pracovísk celého sveta po explantácii pre ich opacifikáciu. Po návrate z USA som od roku 2005 ako sekundárny lekár Očnej kliniky Slovenskej zdravotníckej univerzity FNsP F.D. Roosevelta v Banskej Bystrici pokračovala v analýze explantovaných umelých vnútroočných šošoviek v spolupráci s horeuvedenými americkými pracoviskami ako aj s novovzniknutým európskym pracoviskom BERI v Berlíne. V Banskej Bystrici bola vykonaná analýza 7 opacifikovaných umelých vnútroočných šošoviek (3 MemoryLens, 1 Aqua Sense, 1 Sofcryl, 1 Oculentis a 1 Acrysof). Pomocou komplexu vyšetrovacích metód (Gross makroskopická a mikroskopická analýza, histochemické farbenia alizarínovou červeňou a metódou von Kossa, elektrónova rastrovacia mikroskopia - SEM a RTG spektroskopická analýza - EDS) sme dokázali,...cs_CZ
uk.abstract.enOver the years of 2000 trough 2003 I had worked at two Centers of Ophthalmology in USA. During my fellowship at Center for Reaserch on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina and at John A. Moran Eye Center University of Utah, Salt Lake City, Utah, I had worked as a member of Apple Korps team on the analyses of four various hydrofilic acrylic intraocular lenses (Hydroview H60M, SC60B-OUV, Aqua Sense a MemoryLens). These explanted IOLs were sent to our Centers from the Ophthalmology Clinics from all over the world due to their opacification. Since the year 2005, after my return from the USA, as an ophthalmologist of Eye Clinic F.D. Roosevelt Hospital, Postgraduate Medical School in Banska Bystrica, I continued working on the analyses of explanted IOLs in close cooperation with above specified US Centers as well as with at the time freshly established European Center BERI in Berlin. Analyses of 7 opacificated IOLs (3 MemoryLens, 1 Aqua Sense, 1 Sofcryl, 1 Oculentis and 1 Acrysof ) was performed at the Eye Clinic in Banska Bystrica. Using examination methods (such as gross macroscopic and microscopic analyses, histochemical staining using Alizarin red and von Kossa method, Scanning electron microscopy -SEM and Electron...en_US
uk.file-availabilityV
uk.grantorUniverzita Karlova, Lékařská fakulta v Hradci Králové, Oční klinikacs_CZ
thesis.grade.codeP
uk.publication-placeHradec Královécs_CZ
dc.identifier.lisID990017086880106986


Soubory tohoto záznamu

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

Tento záznam se objevuje v následujících sbírkách

Zobrazit minimální záznam


© 2017 Univerzita Karlova, Ústřední knihovna, Ovocný trh 560/5, 116 36 Praha 1; email: admin-repozitar [at] cuni.cz

Za dodržení všech ustanovení autorského zákona jsou zodpovědné jednotlivé složky Univerzity Karlovy. / Each constituent part of Charles University is responsible for adherence to all provisions of the copyright law.

Upozornění / Notice: Získané informace nemohou být použity k výdělečným účelům nebo vydávány za studijní, vědeckou nebo jinou tvůrčí činnost jiné osoby než autora. / Any retrieved information shall not be used for any commercial purposes or claimed as results of studying, scientific or any other creative activities of any person other than the author.

DSpace software copyright © 2002-2015  DuraSpace
Theme by 
@mire NV