dc.contributor.advisor | Rešlová, Taťána | |
dc.creator | Musilová, Ivana | |
dc.date.accessioned | 2020-11-26T17:08:05Z | |
dc.date.available | 2020-11-26T17:08:05Z | |
dc.date.issued | 2011 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/34889 | |
dc.description.abstract | Objective: To evaluate the efficiency of selected doppler parameters as a test for the prediction of twin growth discordancy (GD) and to compare it with the efficiency of routinely used ultrasound biometrical parameters. Design: Prospective clinical study. Methods: Set was formed by 63 twin pregancies. Intertwin differences in Doppler parameters (umbilical artery - AU, middle cerebral artery - MCA, cerebroplacental ratio - CPR) and biometrical parameters (biparietal diameter - BPD, abdominal circumference - AC, femur length - FL, estimated fetal weight - EFW) were studied. Simultaneously, uterine arteries impedance was assessed. GD was identified by the birth weight difference from 20%. The efficiency of intertwin differences in studied parameters were evaluated using ROC analysis. Results: Biometrical measurements performed within three weeks antepartum were in prediction of GD more accurate than doppler parameters (AUC for EFW 0.99; for AU 0.56; for CPR 0.71). Three to six weeks antepartum, the efficiency of biometrical and doppler parameters was comparable (AUC for EFW 0.79; for AU 0.81; for CPR 0.81). In interval more than six weeks antepartum, biometrical parameters were not effective, DG was predictable only using CPR (AUC for EFW 0.62; for AU 0.56; for CPR 0.77). No significant differences... | en_US |
dc.description.abstract | Cíl studie: Zhodnotit efektivitu vybraných dopplerovských parametrů jako testu predikce diskordantního růstu (DR) a porovnat ji s efektivitou rutinně používaných ultrazvukových biometrických parametrů. Typ studie: Prospektivní klinická studie. Soubor a metodika: Soubor tvořilo 63 dvojčetných gravidit s celkovým počtem 142 vyšetření. Byly studovány rozdíly mezi oběma plody v dopplerovských parametrech (arteria umbilicalis - AU, arteria cerebri media - ACM, cerebro-placentární poměr - CPR) a biometrických parametrech (biparietální průměr - BPD, obvod břicha - AC, délka femuru - FL, odhad fetální hmotnosti - EFW). Současně byla sledována i rezistence uterinních arterií. Za DR byl považován rozdíl porodních hmotností od 20% výše. Efektivita interfetálních rozdílů sledovaných parametrů byla zhodnocena pomocí ROC analýzy. Výsledky: Biometrie provedená do 3 týdnů před porodem byla pro predikci DR růstu přesnější než dopplerovská flowmetrie (AUC pro EFW 0.99; pro AU 0.56; pro CPR 0.71). Při vyšetření v rozmezí 3-6 týdnů před porodem byla efektivita biometrických a dopplerovských parametrů srovnatelná (AUC pro EFW 0.79; pro AU 0.81; pro CPR 0.81). S odstupem více jak 6 týdnů před porodem nebyla již biometrie efektivní, z dopplerovských parametrů predikoval DR jen CPR (AUC pro EFW 0.62; pro AU 0.56; pro CPR... | cs_CZ |
dc.language | Čeština | cs_CZ |
dc.language.iso | cs_CZ | |
dc.publisher | Univerzita Karlova, Lékařská fakulta v Hradci Králové | cs_CZ |
dc.title | Možnosti užití dopplerovské flowmetrie v detekci diskordantního růstu dvojčat | cs_CZ |
dc.type | dizertační práce | cs_CZ |
dcterms.created | 2011 | |
dcterms.dateAccepted | 2011-05-31 | |
dc.description.department | Department of Obstetrics and Gynecology | en_US |
dc.description.department | Porodnická a gynekologická klinika | cs_CZ |
dc.description.faculty | Lékařská fakulta v Hradci Králové | cs_CZ |
dc.description.faculty | Faculty of Medicine in Hradec Králové | en_US |
dc.identifier.repId | 81448 | |
dc.title.translated | Possible use of doppler flowmetry in the detection of discordant growth of twins | en_US |
dc.contributor.referee | Měchurová, Alena | |
dc.contributor.referee | Ľubušký, Marek | |
dc.identifier.aleph | 001364611 | |
thesis.degree.name | Ph.D. | |
thesis.degree.level | doktorské | cs_CZ |
thesis.degree.discipline | - | cs_CZ |
thesis.degree.discipline | - | en_US |
thesis.degree.program | Gynekologie a porodnictví | cs_CZ |
thesis.degree.program | Gynaecology and Obstetrics | en_US |
uk.thesis.type | dizertační práce | cs_CZ |
uk.taxonomy.organization-cs | Lékařská fakulta v Hradci Králové::Porodnická a gynekologická klinika | cs_CZ |
uk.taxonomy.organization-en | Faculty of Medicine in Hradec Králové::Department of Obstetrics and Gynecology | en_US |
uk.faculty-name.cs | Lékařská fakulta v Hradci Králové | cs_CZ |
uk.faculty-name.en | Faculty of Medicine in Hradec Králové | en_US |
uk.faculty-abbr.cs | LFHK | cs_CZ |
uk.degree-discipline.cs | - | cs_CZ |
uk.degree-discipline.en | - | en_US |
uk.degree-program.cs | Gynekologie a porodnictví | cs_CZ |
uk.degree-program.en | Gynaecology and Obstetrics | en_US |
thesis.grade.cs | Prospěl/a | cs_CZ |
thesis.grade.en | Pass | en_US |
uk.abstract.cs | Cíl studie: Zhodnotit efektivitu vybraných dopplerovských parametrů jako testu predikce diskordantního růstu (DR) a porovnat ji s efektivitou rutinně používaných ultrazvukových biometrických parametrů. Typ studie: Prospektivní klinická studie. Soubor a metodika: Soubor tvořilo 63 dvojčetných gravidit s celkovým počtem 142 vyšetření. Byly studovány rozdíly mezi oběma plody v dopplerovských parametrech (arteria umbilicalis - AU, arteria cerebri media - ACM, cerebro-placentární poměr - CPR) a biometrických parametrech (biparietální průměr - BPD, obvod břicha - AC, délka femuru - FL, odhad fetální hmotnosti - EFW). Současně byla sledována i rezistence uterinních arterií. Za DR byl považován rozdíl porodních hmotností od 20% výše. Efektivita interfetálních rozdílů sledovaných parametrů byla zhodnocena pomocí ROC analýzy. Výsledky: Biometrie provedená do 3 týdnů před porodem byla pro predikci DR růstu přesnější než dopplerovská flowmetrie (AUC pro EFW 0.99; pro AU 0.56; pro CPR 0.71). Při vyšetření v rozmezí 3-6 týdnů před porodem byla efektivita biometrických a dopplerovských parametrů srovnatelná (AUC pro EFW 0.79; pro AU 0.81; pro CPR 0.81). S odstupem více jak 6 týdnů před porodem nebyla již biometrie efektivní, z dopplerovských parametrů predikoval DR jen CPR (AUC pro EFW 0.62; pro AU 0.56; pro CPR... | cs_CZ |
uk.abstract.en | Objective: To evaluate the efficiency of selected doppler parameters as a test for the prediction of twin growth discordancy (GD) and to compare it with the efficiency of routinely used ultrasound biometrical parameters. Design: Prospective clinical study. Methods: Set was formed by 63 twin pregancies. Intertwin differences in Doppler parameters (umbilical artery - AU, middle cerebral artery - MCA, cerebroplacental ratio - CPR) and biometrical parameters (biparietal diameter - BPD, abdominal circumference - AC, femur length - FL, estimated fetal weight - EFW) were studied. Simultaneously, uterine arteries impedance was assessed. GD was identified by the birth weight difference from 20%. The efficiency of intertwin differences in studied parameters were evaluated using ROC analysis. Results: Biometrical measurements performed within three weeks antepartum were in prediction of GD more accurate than doppler parameters (AUC for EFW 0.99; for AU 0.56; for CPR 0.71). Three to six weeks antepartum, the efficiency of biometrical and doppler parameters was comparable (AUC for EFW 0.79; for AU 0.81; for CPR 0.81). In interval more than six weeks antepartum, biometrical parameters were not effective, DG was predictable only using CPR (AUC for EFW 0.62; for AU 0.56; for CPR 0.77). No significant differences... | en_US |
uk.file-availability | V | |
uk.grantor | Univerzita Karlova, Lékařská fakulta v Hradci Králové, Porodnická a gynekologická klinika | cs_CZ |
thesis.grade.code | P | |
uk.publication-place | Hradec Králové | cs_CZ |
dc.identifier.lisID | 990013646110106986 | |