Using of quantitative DNA method as a screening tool for effecient genotyping of samples in forensic DNA laboratory.
Použití metody kvantifikace DNA jako screeningového nástroje pro efektivní genotypování vzorků ve forenzní DNA laboratoři.
diploma thesis (DEFENDED)
View/ Open
Permanent link
http://hdl.handle.net/20.500.11956/33151Identifiers
Study Information System: 67697
Collections
- Kvalifikační práce [20130]
Author
Advisor
Referee
Daňková, Pavlína
Faculty / Institute
Faculty of Science
Discipline
Anthropology and Human Genetics
Department
Department of Anthropology and Human Genetics
Date of defense
7. 6. 2011
Publisher
Univerzita Karlova, Přírodovědecká fakultaLanguage
English
Grade
Good
Keywords (Czech)
DNA quantification, real-time PCR, low level DNA, validation, cut off quantification valueKeywords (English)
DNA quantification, real-time PCR, low level DNA, validation, cut off quantification valueQuantification of human DNA in forensic samples is an important step during STR profiling because the STR genotyping is sensitive to the quantity of DNA used in the PCR reaction. This study focuses on the importance of quantification in the entire process of genetic analysis. Two real time PCR platforms (Roche LightCycler480 System and ABI 7900 RT PCR) were used to compare two commercial kits in terms of DNA quantification. It was found out that accuracy of absolute quantification values in commercial quantification kits is strongly dependent on the construction of calibration curve. Especially low template DNA samples were used to assess whether QuantifilerTM or Plexor® HY System can determinate a minimum quantification value (cut off value) below which STR profiles would consistently fail to be detected. The usage of Plexor® HY System enabled to determine the cut off quantification value more exactly probably due to different molecular background and chemistry used in this kit. Reliability and other issues connected with cut off value are discussed. In order to better understand the relationship between the quantity of DNA and the number of detectable loci series the dilution experiment with standard DNA007 was done. Quantitative and qualitative consequences of input DNA amount in evaluation of...
Quantification of human DNA in forensic samples is an important step during STR profiling because the STR genotyping is sensitive to the quantity of DNA used in the PCR reaction. This study focuses on the importance of quantification in the entire process of genetic analysis. Two real time PCR platforms (Roche LightCycler480 System and ABI 7900 RT PCR) were used to compare two commercial kits in terms of DNA quantification. It was found out that accuracy of absolute quantification values in commercial quantification kits is strongly dependent on the construction of calibration curve. Especially low template DNA samples were used to assess whether QuantifilerTM or Plexor® HY System can determinate a minimum quantification value (cut off value) below which STR profiles would consistently fail to be detected. The usage of Plexor® HY System enabled to determine the cut off quantification value more exactly probably due to different molecular background and chemistry used in this kit. Reliability and other issues connected with cut off value are discussed. In order to better understand the relationship between the quantity of DNA and the number of detectable loci series the dilution experiment with standard DNA007 was done. Quantitative and qualitative consequences of input DNA amount in evaluation of...