dc.contributor.advisor | Cvačka, Josef | |
dc.creator | Rumlová, Barbora | |
dc.date.accessioned | 2019-05-03T18:20:04Z | |
dc.date.available | 2019-05-03T18:20:04Z | |
dc.date.issued | 2018 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/98129 | |
dc.description.abstract | This diploma thesis deals with hyphenation of liquid chromatography with mass spectrometric detection based on microfluidic chip. Firstly, a miniaturized ion source for atmospheric-pressure chemical ionization (APCI), and atmospheric-pressure photoionization (APPI) was constructed. The main component of this source was a glass microfluidic chip. Geometry and the working conditions of the chip were optimized. Since both ion sources work under the same conditions, possible advantages resulting from APCI/APPI combination were investigated. Furthermore, the performance characteristics of the sources were evaluated, and compared to the conventional high flow-rate sources. The best performing source, APCI, was then hyphenated with HPLC using low flow-rate. A method for separation of fatty acids methyl esters using Supelco 37 standard was developed. The separation conditions were as follows: C18 reversed stationary phase, and acetonitrile containing 0.1 % formic acids was used as the mobile phase. A temperature gradient was used in order to enhance the speed of the separation. The limits of detection and quantitation of for selected analytes using the chip micro-APCI were calculated, and compared to the ones obtained using a commercially available micro-APCI source. The method was used for separation of... | en_US |
dc.description.abstract | Tato diplomová práce se zabývá spojením kapalinové chromatografie s hmotnostně- spektrometrickou detekcí na bázi mikrofluidního čipu. Nejprve byl sestaven miniaturizovaný iontový zdroj pro chemickou ionizaci za atmosférického tlaku (APCI) a fotoionizaci za atmosférického tlaku (APPI), jehož hlavní komponentou byl skleněný mikrofluidní čip. Byla optimalizována geometrie a pracovní podmínky zdrojů. Jelikož oba iontové zdroje pracují za stejných podmínek, byly testovány možné výhody kombinovaného zdroje APCI/APPI. Dále byly studovány vlastnosti zdrojů a následně byly porovnávány s konvenčními zdroji pracujícími za vysokých průtoků. Zdroj, který vykazoval nejlepší vlastnosti, tedy APCI, byl spojen s kapalinovou chromatografií za nízkého průtoku. Byla vyvinuta metoda pro separaci methylesterů mastných kyselin pomocí standardu Supelco 37 Component FAME Mix. K separaci bylo využito reverzní chromatografie na stacionární fázi C18 a mobilní fázi obsahující 0,1 % kyseliny mravenčí v acetonitrilu. Pro zrychlení doby analýzy byl použit teplotní gradient. Byl určen limit detekce a limit stanovitelnosti čipového mikro-APCI zdroje a byl porovnán s detekcí pomocí komerčního zdroje v režimu mikro-APCI. Vyvinutá metoda byla použita k separaci methylesterů mastných kyselin ve vzorcích jojobového oleje a oleje z... | cs_CZ |
dc.language | Čeština | cs_CZ |
dc.language.iso | cs_CZ | |
dc.publisher | Univerzita Karlova, Přírodovědecká fakulta | cs_CZ |
dc.subject | HPLC | cs_CZ |
dc.subject | MS | cs_CZ |
dc.subject | mikrofluidika | cs_CZ |
dc.subject | lipidy | cs_CZ |
dc.subject | HPLC | en_US |
dc.subject | MS | en_US |
dc.subject | microfluidics | en_US |
dc.subject | lipids | en_US |
dc.title | Kapalinová chromatografie s hmotnostně-spektrometrickou detekcí na bázi mikrofluidního čipu | cs_CZ |
dc.type | diplomová práce | cs_CZ |
dcterms.created | 2018 | |
dcterms.dateAccepted | 2018-05-31 | |
dc.description.department | Department of Analytical Chemistry | en_US |
dc.description.department | Katedra analytické chemie | cs_CZ |
dc.description.faculty | Faculty of Science | en_US |
dc.description.faculty | Přírodovědecká fakulta | cs_CZ |
dc.identifier.repId | 182832 | |
dc.title.translated | Liquid chromatography with mass-spectrometric detection based on a microfluidic chip | en_US |
dc.contributor.referee | Jelínek, Ivan | |
dc.identifier.aleph | 002189352 | |
thesis.degree.name | Mgr. | |
thesis.degree.level | navazující magisterské | cs_CZ |
thesis.degree.discipline | Analytická chemie | cs_CZ |
thesis.degree.discipline | Analytical Chemistry | en_US |
thesis.degree.program | Chemie | cs_CZ |
thesis.degree.program | Chemistry | en_US |
uk.thesis.type | diplomová práce | cs_CZ |
uk.taxonomy.organization-cs | Přírodovědecká fakulta::Katedra analytické chemie | cs_CZ |
uk.taxonomy.organization-en | Faculty of Science::Department of Analytical Chemistry | en_US |
uk.faculty-name.cs | Přírodovědecká fakulta | cs_CZ |
uk.faculty-name.en | Faculty of Science | en_US |
uk.faculty-abbr.cs | PřF | cs_CZ |
uk.degree-discipline.cs | Analytická chemie | cs_CZ |
uk.degree-discipline.en | Analytical Chemistry | en_US |
uk.degree-program.cs | Chemie | cs_CZ |
uk.degree-program.en | Chemistry | en_US |
thesis.grade.cs | Výborně | cs_CZ |
thesis.grade.en | Excellent | en_US |
uk.abstract.cs | Tato diplomová práce se zabývá spojením kapalinové chromatografie s hmotnostně- spektrometrickou detekcí na bázi mikrofluidního čipu. Nejprve byl sestaven miniaturizovaný iontový zdroj pro chemickou ionizaci za atmosférického tlaku (APCI) a fotoionizaci za atmosférického tlaku (APPI), jehož hlavní komponentou byl skleněný mikrofluidní čip. Byla optimalizována geometrie a pracovní podmínky zdrojů. Jelikož oba iontové zdroje pracují za stejných podmínek, byly testovány možné výhody kombinovaného zdroje APCI/APPI. Dále byly studovány vlastnosti zdrojů a následně byly porovnávány s konvenčními zdroji pracujícími za vysokých průtoků. Zdroj, který vykazoval nejlepší vlastnosti, tedy APCI, byl spojen s kapalinovou chromatografií za nízkého průtoku. Byla vyvinuta metoda pro separaci methylesterů mastných kyselin pomocí standardu Supelco 37 Component FAME Mix. K separaci bylo využito reverzní chromatografie na stacionární fázi C18 a mobilní fázi obsahující 0,1 % kyseliny mravenčí v acetonitrilu. Pro zrychlení doby analýzy byl použit teplotní gradient. Byl určen limit detekce a limit stanovitelnosti čipového mikro-APCI zdroje a byl porovnán s detekcí pomocí komerčního zdroje v režimu mikro-APCI. Vyvinutá metoda byla použita k separaci methylesterů mastných kyselin ve vzorcích jojobového oleje a oleje z... | cs_CZ |
uk.abstract.en | This diploma thesis deals with hyphenation of liquid chromatography with mass spectrometric detection based on microfluidic chip. Firstly, a miniaturized ion source for atmospheric-pressure chemical ionization (APCI), and atmospheric-pressure photoionization (APPI) was constructed. The main component of this source was a glass microfluidic chip. Geometry and the working conditions of the chip were optimized. Since both ion sources work under the same conditions, possible advantages resulting from APCI/APPI combination were investigated. Furthermore, the performance characteristics of the sources were evaluated, and compared to the conventional high flow-rate sources. The best performing source, APCI, was then hyphenated with HPLC using low flow-rate. A method for separation of fatty acids methyl esters using Supelco 37 standard was developed. The separation conditions were as follows: C18 reversed stationary phase, and acetonitrile containing 0.1 % formic acids was used as the mobile phase. A temperature gradient was used in order to enhance the speed of the separation. The limits of detection and quantitation of for selected analytes using the chip micro-APCI were calculated, and compared to the ones obtained using a commercially available micro-APCI source. The method was used for separation of... | en_US |
uk.file-availability | V | |
uk.publication.place | Praha | cs_CZ |
uk.grantor | Univerzita Karlova, Přírodovědecká fakulta, Katedra analytické chemie | cs_CZ |
thesis.grade.code | 1 | |
dc.identifier.lisID | 990021893520106986 | |