dc.contributor.advisor | Tichý, Milan | |
dc.creator | Picková, Irena | |
dc.date.accessioned | 2018-11-30T11:57:13Z | |
dc.date.available | 2018-11-30T11:57:13Z | |
dc.date.issued | 2014 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/63419 | |
dc.description.abstract | This work deals with the study of dissociation of iodine molecule for Chemical and Discharge Oxygen-Iodine Laser. Chemical way of HI dissociation and discharge way of dissociation of CH3I and CF3I molecules is examined. Main diagnostics method is absorption spectroscopy. Part of the work is also the modeling of system of chemical reactions. Last part of this work is dealing with the study of plasma generated by the radiofrequency generator in the hollow cathode plasma jet system using argon or mixture of argon with iodine. Diagnostic method used is Langmuir probe. | en_US |
dc.description.abstract | Tato práce se zabývá studiem disociace jodových molekul v souvislosti s vývojem chemického a výbojového kyslík-jodového laseru. Byla zkoumána chemická disociace molekuly HI a výbojová disociace molekul CH3I a CF3I. Hlavní diagnostickou metodou je absorpční spektroskopie. Součástí práce je modelování systému chemických rovnic. Na základní část práce navazuje zkoumání plazmatu buzeného radiofrekvenčním zdrojem v plazmatické trysce s dutou katodou v argonu a ve směsi argonu s jodem metodou Langmuirovy sondy. | cs_CZ |
dc.language | English | cs_CZ |
dc.language.iso | en_US | |
dc.publisher | Univerzita Karlova, Matematicko-fyzikální fakulta | cs_CZ |
dc.subject | Chemical laser | en_US |
dc.subject | iodine | en_US |
dc.subject | plasma | en_US |
dc.subject | radiofrequency | en_US |
dc.subject | electronegative | en_US |
dc.subject | Chemický laser | cs_CZ |
dc.subject | jod | cs_CZ |
dc.subject | plazma | cs_CZ |
dc.subject | radiofrekvence | cs_CZ |
dc.subject | elektronegativní | cs_CZ |
dc.title | Study of the Chemical Oxygen-iodine Laser with the production of atomic iodine from gaseous compounds | en_US |
dc.type | dizertační práce | cs_CZ |
dcterms.created | 2014 | |
dcterms.dateAccepted | 2014-09-12 | |
dc.description.department | Katedra fyziky povrchů a plazmatu | cs_CZ |
dc.description.department | Department of Surface and Plasma Science | en_US |
dc.description.faculty | Faculty of Mathematics and Physics | en_US |
dc.description.faculty | Matematicko-fyzikální fakulta | cs_CZ |
dc.identifier.repId | 43485 | |
dc.title.translated | Studium chemického kyslík-jodového laseru s produkcí atomárního jodu z plynných sloučenin | cs_CZ |
dc.contributor.referee | Čada, Martin | |
dc.contributor.referee | Krčma, František | |
dc.identifier.aleph | 001862544 | |
thesis.degree.name | Ph.D. | |
thesis.degree.level | doktorské | cs_CZ |
thesis.degree.discipline | Fyzika plazmatu a ionizovaných prostředí | cs_CZ |
thesis.degree.discipline | Physics of Plasma and Ionized Media | en_US |
thesis.degree.program | Physics | en_US |
thesis.degree.program | Fyzika | cs_CZ |
uk.thesis.type | dizertační práce | cs_CZ |
uk.taxonomy.organization-cs | Matematicko-fyzikální fakulta::Katedra fyziky povrchů a plazmatu | cs_CZ |
uk.taxonomy.organization-en | Faculty of Mathematics and Physics::Department of Surface and Plasma Science | en_US |
uk.faculty-name.cs | Matematicko-fyzikální fakulta | cs_CZ |
uk.faculty-name.en | Faculty of Mathematics and Physics | en_US |
uk.faculty-abbr.cs | MFF | cs_CZ |
uk.degree-discipline.cs | Fyzika plazmatu a ionizovaných prostředí | cs_CZ |
uk.degree-discipline.en | Physics of Plasma and Ionized Media | en_US |
uk.degree-program.cs | Fyzika | cs_CZ |
uk.degree-program.en | Physics | en_US |
thesis.grade.cs | Prospěl/a | cs_CZ |
thesis.grade.en | Pass | en_US |
uk.abstract.cs | Tato práce se zabývá studiem disociace jodových molekul v souvislosti s vývojem chemického a výbojového kyslík-jodového laseru. Byla zkoumána chemická disociace molekuly HI a výbojová disociace molekul CH3I a CF3I. Hlavní diagnostickou metodou je absorpční spektroskopie. Součástí práce je modelování systému chemických rovnic. Na základní část práce navazuje zkoumání plazmatu buzeného radiofrekvenčním zdrojem v plazmatické trysce s dutou katodou v argonu a ve směsi argonu s jodem metodou Langmuirovy sondy. | cs_CZ |
uk.abstract.en | This work deals with the study of dissociation of iodine molecule for Chemical and Discharge Oxygen-Iodine Laser. Chemical way of HI dissociation and discharge way of dissociation of CH3I and CF3I molecules is examined. Main diagnostics method is absorption spectroscopy. Part of the work is also the modeling of system of chemical reactions. Last part of this work is dealing with the study of plasma generated by the radiofrequency generator in the hollow cathode plasma jet system using argon or mixture of argon with iodine. Diagnostic method used is Langmuir probe. | en_US |
uk.file-availability | V | |
uk.publication.place | Praha | cs_CZ |
uk.grantor | Univerzita Karlova, Matematicko-fyzikální fakulta, Katedra fyziky povrchů a plazmatu | cs_CZ |
thesis.grade.code | P | |
dc.identifier.lisID | 990018625440106986 | |